| JBOD Connection Interface | SAS | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Drive Bay | 16 x 3,5 pollici | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Drive Compatibility | Bay da 3,5 pollici: 3,5 pollici SAS 12Gb/s, 6Gb/s dischi rigidi
 3,5 pollici SATA 6Gb/s, 3Gb/s dischi rigidi
 2,5 pollici SATA 6Gb/s, 3Gb/s stato solido dischi rigidi
 È possibile utilizzare solo un tipo di disco (HDD o SSD) in un gruppo RAID. La combinazione di diversi tipi di disco in un unico gruppo RAID non è supportata. | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Hot-swappable |  | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Form Factor | 3U Rackmount | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Host Interface | Tre SAS (uno di ingresso, uno di uscita, uno riservato) 12Gbps per ogni controller, 4 porte | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | LED Indicators | LED di alimentazione sistema (Verde): acceso/spento Stato del sistema (Verde/Arancione): in funzionamento, errori di sistema, bassa potenza, modalità RAID degradata, fallimento della memoria, fallimento ventola/alimentazione, temperatura sistema/disco troppo alta, pool di memorizzazione raggiunge valore soglia, sistema in esecuzione di take-over, unità di alimentazione scollegata
 Display Stato LCD (Numero a due cifre): Stato della connessione JBOD
 | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Buttons | Alimentazione / Reset | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Dimensions (HxWxD) | 132 × 446,2 × 618 mm Esclude l’occhiello e la parte sporgente dell’alimentatore. | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Weight (Net) | 29.2 kg | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Weight (Gross) | 33.8 kg | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Operating Temperature | 0 - 40°C (32°F - 104°F) | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Storage Temperature | -20 - 70°C (-4°F - 158°F) | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Relative Humidity | 5~95% RH non condensante, bulbo umido: 27℃ (80.6℉) | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Power Supply Unit | Alimentatore ATX ridondante/Hot Swap, 450W, 90-240Vac~, 50-60Hz | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Power Consumption: Operating Mode, Typical | 344.19 W Test con dischi tutti popolati. | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Fan | Modulo ventola sostituibile a caldo (60*60*38mm; 16000RPM/12v/2.8A x 3) | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | System Warning | Cicalino | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | QES |  | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Supports JBOD cascading |  | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Supports Multi-path |  | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Dual-controller design (HA) |  | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Standard Warranty | 5 | 
                                                                                                                                                                                                                                                                                                                                                                                                                                                     | Management | Le funzioni elencate di seguito sono gestite tramite il sistema operativo QNAP QES. 
 Supporto per la capacità S.M.A.R.T. del disco fisso
 Identificatore LED dell'enclosure di espansione RAID
 Indicazione della posizione dell'enclosure di espansione RAID
 Indicazione della posizione dei dischi fissi sull'enclosure di espansione RAID
 Controllo intelligente della ventola
 Aggiornamento firmware in-band
 I dischi, i gruppi RAID, i pool di archiviazione e i volumi negli enclosure di espansione RAID sono configurati tramite il sistema operativo QES.
 
 Fino a 1PB Volume Singolo
 Supporto per più gruppi RAID in un pool di archiviazione per garantire la sicurezza dei dati
 Espansione del pool di archiviazione online
 Espansione del volume online
 LUN iSCSI basato su blocchi
 Supporto per volume con provisioning dinamico con reclamo dello spazio
 Supporto per LUN iSCSI con provisioning dinamico con reclamo dello spazio
 |