ES1640dc v2 Specification

  1. ES1640dc-v2-E5-96G (Legacy)

    Số mô-đun điều khiển 2
    CPU Intel Xeon E5-2400 v2 family processor
    Intel Xeon 6-core Processor E5-2420 v2 (15M Cache, 2.20GHz)
    CPU Architecture 64-bit x86
    Floating Point Unit
    Encryption Engine (AES-NI)
    System Memory 48 GB RDIMM DDR3 ECC (3 x 16 GB) per controller
    Memory Slot 3 x RDIMM DDR3 for each controller
    32GB Main Memory + 16GB write cache PER CONTROLLER.
    Flash Memory 2 GB
    Drive Bay 16 x 3.5-inch
    SAS 12Gb/s, backward-compatible to SAS 6Gb/s
    Drive Compatibility 3.5-inch bays:
    3.5-inch SAS hard disk drives
    2.5-inch SAS hard disk drives
    2.5-inch SAS solid state drives
    Hot-swappable
    SSD Cache Acceleration Support
    Cache for Copy To Flash (C2F) 1 per each controller
    (M.2 2280 SSD dedicated to NVRAM, SATA signaling)
    Gigabit Ethernet Port (RJ45) 1 for each controller (for remote management)
    10 Gigabit Ethernet Port 4 x 10GbE SFP+ (Intel XL710-AM1) and 2 x 10GBASE-T (LAN-10G2T-X550) for each controller
    Wake on LAN (WOL)
    Jumbo Frame
    PCIe Slot PCIe Slot x8 (Gen 3 x8): Pre-installed with a LAN-10G2T-X550 NIC (2 x 10GbE RJ45 ports), replacable with a 40GbE NIC
    PCIe Slot x4 (Gen 2 x4): Pre-installed with a dual-port Mini-SAS adapter
    USB 3.2 Gen 1 port 2 per each controller
    Note: The USB ports are for engineering purpose only. No external devices such as storage drives or UPS are supported.
    Form Factor 3U Rackmount
    LED Indicators System Power LED (Green): on/off
    System Status (Green/ Orange): in operation, system errors, low power, degraded RAID mode, memory failure, fan/power supply failure, system/disk temperature too high, storage pool reaching threshold value, system performing take-over, power supply unit unplugged
    LCD Status Display (Two-digit number): Status of JBOD connection
    Buttons Power, Reset
    Dimensions (HxWxD) 132 × 446.2 × 618 mm
    Weight (Net) 26.75 kg
    Weight (Gross) 36.94 kg
    Operating Temperature 0 - 40 °C (32°F - 104°F)
    Storage Temperature -20 - 70°C (-4°F - 158°F)
    Relative Humidity 5-95% RH non-condensing, wet bulb: 27˚C (80.6˚F)
    Power Supply Unit Redundant/ Hot Swap Power Vin:90~264VAC;770W
    Power Consumption: Operating Mode, Typical 501.4 W
    Tested with drives fully populated.
    Fan Hot-swappable fan module (60*60*38mm; 16000RPM/12v/2.8A x 3)
    System Warning Buzzer
    Standard Warranty 5
    Max. Number of Concurrent Connections (CIFS) - with Max. Memory 10000
    Safety Standard FCC Class A (USA only)
    CE Mark ( EN55022 Class A, EN55024)
    EN60950
    BSMI
    VCCI
    CB
    LVD
    Lưu ý: Chỉ sử dụng các module bộ nhớ QNAP để duy trì hiệu suất và độ ổn định của hệ thống. Đối với các thiết bị NAS có nhiều hơn một khe cắm bộ nhớ, sử dụng các module QNAP có thông số kỹ thuật giống hệt nhau và tham khảo hướng dẫn sử dụng phần cứng để cài đặt các module bộ nhớ QNAP tương thích.
    Cảnh báo: Sử dụng các module không được hỗ trợ có thể làm giảm hiệu suất, gây ra lỗi hoặc ngăn hệ điều hành khởi động.
    QNAP có quyền thay thế các bộ phận hoặc phụ kiện nếu bản gốc không còn có sẵn từ nhà sản xuất/nhà cung cấp. Bất kỳ sự thay thế nào cũng sẽ được kiểm tra và xác minh đầy đủ để đáp ứng các hướng dẫn nghiêm ngặt về tính tương thích và độ ổn định và sẽ mang lại hiệu suất tương tự như bản gốc.
    Các thuật ngữ HDMI, HDMI High-Definition Multimedia Interface, HDMI trade dress và các logo HDMI là các nhãn hiệu hoặc nhãn hiệu đã đăng ký của HDMI Licensing Administrator, Inc.
    Hình ảnh sản phẩm chỉ mang tính minh họa và có thể khác với sản phẩm thực tế. Do sự khác biệt về màn hình, màu sắc của sản phẩm cũng có thể khác so với những gì được hiển thị trên trang web.
    Thiết kế và thông số kỹ thuật có thể thay đổi mà không cần thông báo trước.
  1. Operating System

    QES 2.2.1

    Supported Languages

    Chinese (Traditional & Simplified), Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese (Brazil), Romanian, Russian, Spanish, Swedish, Thai, Turkish

    Storage Pool

    Shared Folder Type

    Thick, Thin

    JBOD Expansion

    LUN Type

    Thick, Thin

    Storage QoS

    Storage Management
    1. NVRAM write cache (BBU-protected)
    2. Scheduled Backup Battery Unit (BBU) learning
    3. Pool scrub for data verification
    4. Share folder quota management
    5. Inline deduplication for shared folder/LUN
    6. Inline compression for shared folder/LUN
    7. Inline encryption for shared folder/LUN
    8. WORM (Write Once Read Many) for shared folder
    9. Online pool, share folder, and LUN expansion
    10. Time-Limited Error Recovery (TLER)
    11. JBOD ID Reinitialized
    12. Support optional fibre channel
    13. Support expanding the capacity of the storage pool by replacing the disks with larger ones
    Show more...
    RAID Type

    RAID 0, 1, 5, 6, 10, 50, 60, RAID TP, triple Mirror

    RAID Group

    To ensure data security, system stability, and storage performance, the maximum number of drives for a single RAID group is now 16 (applicable to RAID 5, RAID 6, RAID TP, and subgroups of RAID 50 and RAID 60). Nevertheless, users can combine multiple RAID groups into a large storage pool that contains more than 16 drives, using RAID 50, RAID 60, or RAID 10 as the RAID configuration. This enhancement will only be applied to new RAID groups. All existing RAID groups and storage systems will not be affected.

    RAID Hot Spare

    Global, Local

    End-to-End data integrity

    Silent error detection and self-healing

    Internal drive

    ZFS

    Disk S.M.A.R.T. Scan

    Disk S.M.A.R.T. Data Migration

    SSD Trim

    SSD Life Estimation

    Shared Folder Snapshot

    LUN Snapshot

    Backup Station
    1. Remote replication server over Rsync
    2. Remote replication server over SnapSync
    3. Real-time or scheduled replication over SnapSync
    4. Compression and Dedupication over SnapSync
    5. Support Veeam Backup & Replication
    Show more...
    File Server
    1. Shared folder for CIFS/SMB, NFS and FTP
    2. File sharing across Windows, Mac, and Linux/UNIX
    3. Windows ACL
    FTP Server
    1. FTP over SSL/TLS (Explicit)
    2. FXP support
    3. Passive ftp port range control
    Access Right Management
    1. Batch users creation
    2. Import/Export users
    3. User quota management
    4. Local user access control for CIFS/SMB and FTP
    Domain Authentication Integration
    1. Microsoft Active Directory support
    2. LDAP client
    3. Domain users login via CIFS/SMB, FTP
    Resource Monitor

    SNMP

    V1, V2, V3

    Network recycle bin

    Network recycle bin for file deletion via CIFS/SMB, File Station and FTP

    System Log & Notification Center
    1. System Log: Yes
    2. Notification Center: -
    Smart Fan

    Administration
    1. Smart file filter
    2. Comprehensive logs (events & connection)
    3. Syslog client management
    4. System settings backup and restore
    5. Command Line Interface (CLI)
    Show more...
    Internet protocol

    IPv4 & IPv6

    10 Gigabit NICs with jumbo frame

    LACP, Load Balance, Failover, Round Robin

    Protocols

    CIFS/SMB2/SMB3, NFS v3/NFS v4.1, FTP, FTPS, TFTP, HTTP, HTTPS, SSH, iSCSI, Fibre Channel, SNMP, SMTP, and SMSC

    iSER

    (iSCSI Extensions for RDMA)

    Bonjour Discovery

    Network access protection with auto-blocking

    SSH, HTTP(S), FTP, CIFS/SMB

    CIFS/SMB host access control for shared folders

    AES 256-bit Volume Encryption validated by FIPS 140-2 CAVP

    AES 256-bit Folder Encryption validated by FIPS 140-2 CAVP

    2-step verification

    Service binding

    (based on network interfaces)

    Importable SSL certificates

    HA Manager

    Fail-over

    Rolling Update

    Thirty Party Plug-ins
    1. SMI-S Provider
    2. vSphere Web Client Plugin​
    3. VAAI Plug-in (Compatible with ESXi 8): NFS, iSCSI
    4. VMware Storage Replication Adapter (SRA)
    5. QNAP Cinder Driver for Openstack block storage
    6. QNAP Manila Driver for Openstack shared file storage
    Show more...
    PC Utilities
    1. Qfinder Pro: Windows, Mac, Linux
    2. myQNAPcloud Connect: Windows
    3. Snapshot agent for Windows VSS and VMware
    4. Qutil (MPIO command line tool for QES)
Lưu ý:
QTS không hỗ trợ nội dung DRM và một số dịch vụ IPv6.
Một số tính năng mã hóa dữ liệu có thể không khả dụng do hạn chế pháp lý cụ thể của từng quốc gia.
Một số tính năng có thể khác nhau tùy theo mẫu.
Thiết kế và thông số kỹ thuật có thể thay đổi mà không cần thông báo trước.
ES1640dc v2 Ethernet cable (10GbE) x 4 Ethernet cable (1GbE) x 2
Power cord x 2 Flat head screw x 64 (for 3.5" HDD) Flat head screw x 64 (for 2.5" HDD)
E02 series (Chassis) rail kit, max. load 57kg: RAIL-E02 Quick Installation Guide Console Cable (RJ11 to RS-232) x 1
Battery Backup Unit for NVRAM write cache x 2 OS Drives Sticker x 4 HDD Tray SSD/HDD Sticker x 16

Chọn thông số kỹ thuật

      Xem thêm Thu gọn

      Choose Your Country or Region

      open menu
      back to top