What should I do if medium errors occur?


Last modified date: 2022-12-06

Applicable Products

QTS, QuTS hero


Root Cause

If you see the following message in the System Even Log, your system may have encountered medium errors.

[Hardware Status] Disk X: Medium error.

Note
This message is only to inform you of medium errors. As long as your storage pools are functional, your data will not be damaged or lost.

This error occurs when the system cannot successfully access the data on your device. We can detect medium errors by verifying data with a checksum, which is a value used to detect errors introduced during data transmission or storage. Checksum mismatch is usually caused by data corruption, also known as bad blocks, often due to long-time use of devices and disks. 

Medium errors can be either temporary or permanent. Your devices sometimes can recover from medium errors. One of the common consequences of medium errors is longer I/O latency, which occurs because your device is attempting to recover from these errors. 


Solution

Follow these steps to identify and resolve this issue.

  1. Go to Storage & Snapshots > Storage > Disk/VJBOD.
  2. Select a disk.
  3. Click Disk Health.
  4. Check disk health summary and S.M.A.R.T. information.
    Tip
    S.M.A.R.T. attributes are indicators for predicting disk health. You may see Warning or Error if some S.M.A.R.T. attributes reach the thresholds defined by disk manufacturers or QNAP.
  5. Go to Test and then run a S.M.A.R.T. test. 

Sometimes you can swap disks in their drive bays to work around medium errors, but if these issues persist, you may have bad blocks on your disks and need to replace them.

If the status of a disk has turned into Warning in S.M.A.R.T. disk information, we recommend replacing the disk soon, as it may fail in the near future. If the status of a disk has turned into Error, it must be replaced immediately. You can click Raid Group to find the RAID group to which an abnormal or faulty disk belongs and identify its RAID type.


Further Reading

Was this article helpful?

50% of people think it helps.
Thank you for your feedback.

Please tell us how this article can be improved:

If you want to provide additional feedback, please include it below.

Teknik Özellik sSçin

      Daha fazla göster Daha az
      Diğer ülkelerde/bölgelerde bu site:
      open menu
      back to top