When the RAID volume operates normally, the volume status is shown as Ready under 'Disk Management' > 'Volume Management' section.
When RAID volume operates normally, the volume status is shown as Ready in the Current Disk Volume Configuration section.
- The server beeps for 1.5 sec twice when the drive fails.
- The Status LED flashes red continuously.
- Check the Current Disk Volume Configuration section. The volume status is In degraded mode.
- You can check the error and warning messages for drive failure and disk volume in degraded mode respectively in the Event Logs.
Please follow the steps below to hot swap the failed hard drive:
- Prepare a new hard drive to rebuild RAID 5. The capacity of the new drive should be at least the same as that of the failed drive.
- Insert the drive to the drive slot of the server. The server beeps for 1.5 seconds twice. The Status LED flashes red and green alternatively.
- Check the Current Disk Volume Configuration section. The volume status is Rebuilding and the progress is shown.
- When the rebuilding is completed, the Status LED lights in green and the volume status is Ready. RAID 5 mirroring protection is now active.
- You can check the disk volume information in the Event Logs.